how to change fan speed on a trane furnace

Realizing this after a very long period of investigation, I eventually turned up the fan speed dial; this seemed to correct the problem initially, until one night a week later lying in bed I heard it do the same thing but but after a much longer run time. Not every AC or furnace filter will have an arrow printed on the frame, but when it does the arrow indicates the direction the filter must face. The system also accounts for blocked vents and dirty furnace filters, and adjusts fan speed as needed to compensate. The boiler is feeding a DHW sidearm and furnace plenum HX. When one of the taps is powered with 24v, the motor will turn on and run at the selected speed. I know I need to replace a dying blower motor in a 1992 Trane . The arrow should point toward the unit. For example, on a package unit, only taps 3, 4 and 5 may be programmed. The blower/fan seems to be running way to fast. Here's hoping for some good answers. In terms of heat pumps, running the external blower faster may reduce i2r copper losses and hysteresis iron eddy current losses. They do this by coupling a sophisticated, programmable thermostat to a variable-speed motor. (Trust me, the worst thing that happens to me on the job is having inconclusive results due to insufficient data collection during an expensive and time-intensive study.) Identify those arcade games from a 1983 Brazilian music video. Here are some of them: Better circulation of heated and cooled air. To learn more, see our tips on writing great answers. This will help prevent injury and damage to the furnace fan. Run a jumper from "R" to "Y2" and the blower will run continuously at the second-stage cooling speed. Therefore I again adjusted the speed upward a bit and that seemingly has corrected the problem. But you will have a tough time measuring either on your basement Trane. Since hot air is much lighter . I want to increase volume flow if possible. I have a Carrier furnace/heat pump with an expensive control thermostat that talks directly to the heat pump. The SW2 indicates the air conditioning size. The air handler houses the fan and fan motor and is usually located in the basement or attic. You may freely link The Trane XR80's heavy steel insulated cabinet has two benefits: Holds in more of the heat that you pay for Decreases operating noise Because of its heavy steel insulated cabinet, the XR80 can experience as little as 1% of air leakage. On this control board, there are multiple adjustments for the airflow speeds. All Logos & Trademark Belongs To Their Respective Owners, Maintaining temperature over a longer period of time is more efficient than getting a room to temperature quickly, A lower fan speed ensures your heat pump will run for longer periods of time which is required for the system to go into whats called a defrost mode (. All rights reserved. Any takers? Most homes are best served by a filter with a MERV rating of 8 to 13, but refer to your system's user manual or with a Trane employee for guidance. For this reason, pair your Variable Speed AC unit with one of the following components: Hyperion TAM9 Air Handler, XC 80 Gas Furnace, XC 95M Furnace, or S9V2. There are only a few steps required for most units and having the control will allow you to get your unit to give you the service you need. 01 - Trane Furnace Control Board. Helm is an accomplished DIY craftsman. I'm in the process of re-wiring my blower to run on high with the furnace. American Standard air handler troubleshooting Step 4: Take out the inducer motor. Of course all that heat was lost because of the ridiculous number of vents in our foundation. Iappreciate all the comments, questions, and responses that Ireceive from each of you. Connect the black wire to the manometer. Comfort R should be off if you are using . Trane. If you do, you may not have enough air flow over the heat exchanger, resulting in overheating and eventually a shorter exchanger life span. After a bit of research, (translated: "mad google skills") I found an article claiming that lowering the blower speed may increase efficiency. DoItYourself.com, founded in 1995, is the leading independent View our Privacy Policy here. Usually, gas furnaces have a temp rise of 50F. All rights reserved. Switched it to heat (in which case the furnace board is in control of the fan, not the stat) - got fire, no fan. When your AC unit is working properly, the blower inside your furnace or AC will blow cold air.The cold air is sent through ducts to the living areas and then returns air to be cooled by the evaporator coil. Id check that out first. The fan speed is controlled on the control board for the furnace. The house has a 3 ton trane xl20i and an xv80 (4 ton max). This control board is out of a variable speed furnace with a modulating gas valve that has a variable speed inducer motor. The real fix is to add insulation and install a second system on the second floor of most recently constructed homes with an adequate number of true ducted returns as opposed to the leaking stud-space returns contractors are so fond of. A 1.5 ton AC unit may not be large enough to cool the . -The BTU/HR size is selectable between 48,000 42,000 36,000 or 30,000 BTU/HR. I have also measured that on low speed my furnace requires AT-LEAST 1 hour of constant running to raise my home temp by 6 deg F. On high speed it takes 30-40 min. The constant air turn over at a lower set point keeps the house comfortable. If the blower motor is burned out, replace it. Stage 3 Aux Heating. Dave. This covers speed adjustment on a PSC motor. The blower is set for 400 cfm for a 4 ton outdoor unit, and comfort-R is not enabled (all factory). Motor is an ECM and it makes a low pitched whine sound when in CIRC or when the blower is ramping up or slowing down to stop. -The "System Type" is the CFM per ton to be adjusted between low, normal and high. Copyright . There is a modification that will allow the VS fan to run on high speed at all times while in the AC mode and with the fan "ON" mode. How do I check if this furnace switch the blower to second speed. I understand the reason for slowing the air to remove humidity. Example: 1200 CFM is needed for a 3 ton 36,000 BTU/HR system. You have to switch the wires to the blower motor. In order to determine or change the speed, check the wiring diagram of the furnace/air handler/package unit that the motor is installed in. If there isnt one in your home, turn it off at the breaker box. Use tab to navigate through the menu items. Be sure to check out our previous article on "Adjusting the Furnace/AC Airflow Speed on a 120v PSC Blower Motor" if you haven't read it yet! In order for the filter to work properly, the right size is crucial. You could also use the Temp Rise Formula which you can learn about in our "HVAC Temp Rise Formula used to Measure Airflow CFM" video. In the pictured example above, if the #5 speed tap is programmed for 1600 CFM and #4 is programmed for 1200 CFM and #5 is presently connected to the "Cool" terminal on the control board via the black wire, we know that the unit is running at around 1600 CFM as long as the TESP across the unit is not too high. When the R-G circuit is made, the blower motor operates on heating speed. The control board is communicating with the blower module in order to determine the airflow volume needed. (FYI Filter was clean and furnace was recently serviced all prior to my initial investigation of the short cycling). If you really wanted to be scientific, you could perform an experiment and post the results here. For business related inquires email us at. My main questions are. One fan is inside the house, and one is outside the home. Home House & Components Systems Heating & Cooling System Air Conditioners. A 90 percent-plus furnace needs 150 cfm per 10,000 Btu of input. In order to measure air flow you could use a flow capture hood, a rotating vane anemometer, or a hot wire anemometer. How to Lower the Ouptut of Oversized Furnace. These two losses comprise the magnitude of heat losses. He farmed commercial garden produce for several years. In a gas furnace, (the most common type of furnace used in homes) natural gas is ignited in the burner and the flames heat up the heat exchanger. This will help prevent injury and. Thanks for the reply. To subscribe to this RSS feed, copy and paste this URL into your RSS reader. This means that any time cooling is called for by the control board, 24v will be present on the #4 terminal of the motor module to turn the motor on and to run at roughly 1200 CFM. 1 to 1.5 hours | Install the new motor, adjust it (multispeed and variable speed blowers only), run and test the furnace Installing a blower wheel with the motor shouldn't affect installation time, since the old wheel typically has to be removed to replace the motor. The question is would the trade-off be in favor of less blower energy consumption and more loss through exhaust, or more blower energy consumption and less loss through exhaust. In the example of an ECM 3.0 with a 4 pin connector, the wires are not switched or moved to adjust the airflow settings. I'd like to get some second opinions. Because the slower air velocity over the heat element is transferring fewer BTU units into the circulated air and they simply go up the exhaust pipe. Bundle Packs are a great way to save and get faster shipping! There is another way to wire this, but I can not find it back.. View our Privacy Policy here. to this site, and use it for non-commercial use subject to our terms of use. Many gas-fired, high-efficiency furnaces also save on the electricity required to power the blower motor, though this savings is not factored into the AFUE rating. The house cools off quick - too quick - and feels humid (not sure of the rh%). The blower motor also begins running, but at low rpm. The blower speed for a gas heater is selected so that it is comfortable for the building occupant but also so that the Delta T (Temp Rise) does not continue to rise. *Based on third party testing of particle removal efficiency down to 0.3 microns (2005). Slowly flashing shows your furnace is on and does not need heat. He also builds custom tools for metal working. Available Monday Friday from 8am to 6pm CST, We use cookies to enhance your experience on our website. One of these wires will be coming from the thermostat and the other will go to the outside unit. Using a hammer, lightly tap out the blower motor shaft (fig.6.7) to loosen the blower motor from the fan shroud (fig.6.8). The induction motor begins running. Connect Y2 on thermostat to BK on furnace, and Y2 on the Condensing unit Cut R-BK jumper at Furnace Install R - O jumper at Furnace Connect W2 on thermostat to W2 on furnace (or alternatively, jumper W1 to W2 at furnace and confirm that dip switches are set correctly for Stage Delay if furnace is desired to automatically control heating stages) My first thought was that the unit was oversized, but I figured out how to check the DIP switch settings. I want to do what is best. I Tried a Hands-Free Dog Leash, and I No Longer Dread Walking My Dog, This Simple Trick Can Refresh Your Entire Home, 30 Spring Cleaning Tasks to Add to Your Checklist, Do not Sell or Share My Personal Information. I.e., maybe more heat is now escaping through the exhaust. I think the best bet would be to actually test it for a few months and see. It was working a week ago but just recently when it runs it blows out cold air. He maintains fruit and nut trees along with helping his wife with a vegetable garden. We have a Trane XL80 furnace manual in pdf version that you can download for free. Select Climate from the blue menu on the left side of the page. Mutually exclusive execution using std::atomic? This will show what speed each numbered tap is programmed as. It is about 1300-1400 sq feet, but then the basement was finished at some point, more or less doubling the square footage. Please note that mounting bracket consists of top and bottom brackets joined by 6 metal screws (fig.6.9). After understanding what speed each tap is programmed for, we can make proper airflow adjustments. 4TEE3C10A1 That is excessivly loud. Pollen, dust, clothing and carpet fibers, hair spray, mold spores, Pollen, dust, clothing and carpet fibers, hair, mold spores, legionella, pet dander, Pollen, dust, clothing and carpet fibers, hair spray, mold spores, bacteria, pet dander, cooking oil, most tobacco smoke, smog, Air filters are the first defense against the pollutants in your air, but building a complete air filtration system can help support an even higher quality of indoor air. Are there downsides to this. Thus, my blower can't be using that much electricity on high. Is it Covered Under Homeowners Insurance or a Home Warranty? Move the high-speed wire to low. Why are Suriname, Belize, and Guinea-Bissau classified as "Small Island Developing States"? To ensure our content is always up-to-date with current information, best practices, and professional advice, articles are routinely reviewed by industry experts with years of hands-on experience. Now that would turn the blower speed down on you. in this thread in this sub-forum in the entire site. Warmup.com mentions that it was the original design of radiant floor heat systems by the Romans. #3. In his particular case it was "too much volume" of air so I presume just moving air filters isn't enough (typically you'd need to adjust blower level AFAICT). I got the sv96 100k btu 2stage furnace with variable fan and the xl18 4ton ac unit. HVAC filters help remove dust, dander, and harmful particles from the air inside your home. What sort of strategies would a medieval military use against a fantasy giant? We welcome your comments and suggestions. 3.5 x 400 = 1400 CFM. He is also an HVACR Contracting Business owner of 16 years and holds an NJ HVACR Master License. If you have an HVACR relatedquestion, drop it in the comment section of one of theYouTube videos at theAC Service Tech YouTube Channel and I will do my best to respond. Put the air handler back. Why do many companies reject expired SSL certificates as bugs in bug bounties? However, during the time period while the compressor is not engaged I need to circulate more air on the second floor or it becomes stale. Additionally, they can be identified by the presence of a removable module/bell on the end of the motor. Therefore for anybody thinking to adjust their blower speed to a low setting be mindful and use caution and listen carefully as to how the system is running. I just had a Trane system installed last week and I've been very happy with it! I have a Trane XV90 propane furnace with a variable speed blower. STEP-BY-STEP REPLACEMENT GUIDE Turn off air conditioning / heat from the thermostat. Locate your thermostat on the page and click System Mode. Air filters are typically found behind the return vent door, often located in the ceiling or wall in the central portion of your home. lower efficiency furnace) it is drafting exhaust up the flue which can't be good.

Judge Andrew Nicol Bias, Spring Valley Il Stabbing 2021, Will Congress Win 2024 Astrology, Articles H